Anilam Mini Wizard A163 Manual _best_ ❲99% REAL❳
The Complete Guide to the Anilam Mini Wizard A163: Finding, Using, and Understanding the Manual
The "Dead Battery" Warning
If you power up the A163 and see scrambled lines or "Error 7," the manual tells you the internal lithium battery (BR2325) is dead. Do not unplug the unit before replacing it. The manual procedure is:
- Turn the unit On.
- Replace the battery while under power (carefully) to retain parameters.
- Re-enter your scale factors.
Entering Scale Resolution (Setup Mode)
This is a critical procedure from the manual: anilam mini wizard a163 manual
- Power off the DRO.
- Press and hold the
SU(Setup) button. - While holding
SU, power on the DRO. - Release
SU. The display showsP 01(Parameter 1). - Use
X/Yto scroll to the correct resolution parameter (e.g.,P 05for 5µm scales,P 10for 10µm). - Press
SUto save. The DRO will restart.
Note: Enter the wrong parameter, and your readout will be exactly double or half the actual travel. Consult your glass scale’s specification label. The Complete Guide to the Anilam Mini Wizard
How to Zero the Axis
- Move the table to your reference edge.
- Press the X key (it should light up or flash).
- Press the 0 key, then press Set/Enter.
- Repeat for Y.
Engaging Sample Excerpt (Example: Simple Drill Program)
N10 G21 G17 G90 (mm, XY plane, absolute) N20 G0 X0 Y0 Z5 N30 M3 S1500 (spindle on, clockwise, 1500 RPM) N40 G0 X10 Y10 N50 G43 H01 Z5 (apply tool offset) N60 G81 Z-10 R2 F300 (drill cycle: peck start at Z-10, retract to R=2, feed 300 mm/min) N70 X20 Y10 N80 X30 Y10 N90 G80 (cancel cycle) N100 G0 Z100 N110 M5 N120 M30 Turn the unit On
Tip: Always run a G0 dry run to verify coordinates and clearance before enabling the spindle.
