Error Number 6007 Cadworx ^hot^ May 2026

In CADWorx, Error 6007 is a critical licensing issue that occurs when the software cannot detect or validate an authorized hardware lock (ESL). It is typically categorized alongside other 6000-series licensing errors. smartsupport1.intergraph.com Technical Overview

Error 6007 specifically indicates a failure to communicate with the HASP hardware key

or a network license manager. This effectively prevents the software from launching or performing specific authorized tasks. Common Causes Missing or Disconnected Key

: The physical USB hardware lock (dongle) is not plugged into the workstation or is loose. Driver Issues

: The Sentinel HASP driver is outdated, corrupted, or not installed correctly on the machine. Network Licensing Conflicts

: If using a network key, the client machine may fail to find the server due to firewall settings or incorrect IP configuration in the nethasp.ini Multiple Hardware Locks

: Plugging in two local Intergraph/Hexagon hardware locks can cause conflicts, as CADWorx only reads from one. smartsupport1.intergraph.com Recommended Troubleshooting Steps Check Physical Connection

: Ensure the green or red hardware key is securely plugged in and glowing (indicating it has power). Verify Active Modules HASP ESL Maintenance Utility (often found in the CADWorx Program Group) and click Show ESL Data to confirm which modules are active on your lock. Configure nethasp.ini : For network users, find the nethasp.ini file in the [Product Folder]\Support

folder. Use "Aggressive Search" settings and specify the server's IP address to force a connection. Update Drivers

: Reinstall or update the latest Sentinel HASP drivers from the Hexagon Smart Support portal to ensure compatibility with your Windows version. smartsupport1.intergraph.com

If these steps do not resolve the issue, it is advised to capture a screenshot of the detailed error description and contact technical support with your ESL number file for a network setup? HASP Support Guide - Green and Red Network Key - Intergraph

In CADWorx, Error 6007 is a licensing and hardware lock error that occurs when the software fails to pull a valid license from the designated server or local hardware key. It is categorized within the 6000-series of licensing errors, often appearing alongside similar codes like 6050. Root Causes of Error 6007

The primary cause is a communication failure between the CADWorx client machine and the HASP (Hardware Against Software Piracy) license manager. This typically happens for several reasons:

Network Disconnection: The client machine is not on the same network as the license server.

Remote License Search Failure: The software cannot automatically locate the network key across subnets. error number 6007 cadworx

Module Authorization Conflict: If a local hardware lock is plugged in but doesn't have the required module authorized, CADWorx may fail to check the network lock, leading to a licensing error.

Incorrect Setup: The software is pointing to the wrong IP address or server for its licensing data. Resolution Strategies

To resolve Error 6007, users should follow a systematic troubleshooting process:

Verify Network Connectivity: Use the command prompt to ping the license server to ensure the client machine has a stable connection.

Configure nethasp.ini: If the software still fails to find the license, you must manually force the connection. Locate the nethasp.ini file (typically found in the Assidrv folder) and modify it to point directly to the Server IP Address. Adjust Sentinel Admin Control Center Settings: Access the Sentinel keys management page. Navigate to the Access to Remote License Managers tab.

Check Aggressive Search for Remote Licenses and enter the specific Server IP.

Hardware Lock Audit: Use the HASP ESL Maintenance Utility or Pulse (found in the CADWorx Program Group or Support folder) to check which modules are active on your hardware lock. Ensure that multiple local hardware locks are not plugged into the same machine, as this can cause reading conflicts.

For more specific guidance, you can refer to the official Hexagon PPM Documentation on error numbers. HASP Support Guide - Green and Red Network Key - Intergraph

In CADWorx, Error Number 6007 is a specific licensing error typically associated with the HASP (Hardware Against Software Piracy) Network Key. It generally signifies a failure to pull a valid license from the server. Root Cause and Context

The "deep story" behind this error usually involves a communication breakdown between your workstation (the client) and the licensing server. When you launch CADWorx, the software attempts to verify its license through the HASP HL service. Error 6007 pops up if the software cannot find the network key or if the connection is interrupted. Common Fixes

Verify Network Connectivity: Ensure your machine is on the same network as the license server.

Check the nethasp.ini File: If the error persists, you likely need to modify or create a nethasp.ini file. This file forces the client machine to look at a specific IP address for the server rather than searching the entire network.

This file is typically located in the Assidrv folder after installation.

Hardware Lock Conflict: CADWorx may prioritize a local hardware lock over a network one. If you have a local lock plugged in that isn't authorized for the module you're trying to use, it may trigger a licensing error. In CADWorx, Error 6007 is a critical licensing

For more technical troubleshooting, you can refer to the official Hexagon PPM Documentation. HASP Support Guide - Green and Red Network Key - Intergraph

In CADWorx, Error 6007 is a licensing error typically related to the HASP network key NetHASP configuration

. It indicates that the client machine cannot successfully pull a license from the server. smartsupport1.intergraph.com Common Solutions Verify Network Connectivity

: Ensure the client machine is on the same network as the license server. Use a command prompt to ping the server's IP address or hostname to confirm a stable connection. nethasp.ini

: This file forces the client to look at a specific server for its license. Locate the nethasp.ini file (usually found in the folder within your CADWorx installation). Verify that the [NH_TCPIP] section has the correct NH_SERVER_ADDR set to your license server's IP address. Update License Drivers

: Ensure you have the latest Sentinel HASP drivers installed on both the client and the server. Firewall Settings : Check that your firewall is not blocking (the default port for HASP licensing). smartsupport1.intergraph.com Troubleshooting Steps CADWORXABOUT

command in your CAD platform to check your current version and license status.

If the error persists, you may need to reset your profile using the Setup Profile utility or contact Hexagon PPM Support for further assistance. Autodesk Community, Autodesk Forums, Autodesk Forum file to manually point to your server? Error messages in CadWorx - Autodesk Community

Error Number 6007 in CADWorx generally refers to a licensing failure where the software cannot communicate with the hardware lock or license server. This "6000-series" error typically indicates that the Sentinel HASP/HL license manager is unable to find a valid license to pull. Common Causes

Network Connectivity: The client machine cannot see the license server on the local network.

Firewall Blocking: Security software or Windows Firewall is preventing communication between the CADWorx client and the license server.

Corrupt/Missing Configuration: The nethasp.ini file, which tells the client where to look for the license, is missing or incorrectly configured.

Driver Issues: The HASP drivers are outdated or were replaced by another software installation. Troubleshooting Steps

Verify Hardware Lock Status:Ensure the red or green network key is physically plugged into the server and that the light is on. For network storage: Ensure every CADWorx user has

Check Network Path:Open a command prompt and try to ping the server's IP address from the client machine to confirm they are on the same network.

Configure Nethasp.ini:If the software still fails to find the license, you must manually point it to the server:

Locate the nethasp.ini file (typically found in the Assidrv folder after installation).

Edit the file to include the specific Server IP Address under the [NH_TCPIP] section.

Update Drivers:Reinstall the latest HASP drivers from the [Product Folder]\Utilities folder or download them from the Hexagon Smart Support portal.

Aggressive Search:In the Sentinel Admin Control Center, go to Configuration > Access to Remote License Managers and check "Aggressive Search for Remote Licenses".

If these steps don't resolve the issue, you may need to check the Event Viewer for more specific error strings or contact Hexagon Technical Support with a screenshot of the detailed error description. Error messages in CadWorx - Forums, Autodesk

Solution 3: Check File Permissions (Especially on Network Drives)

Error 6007 is notorious in multi-user environments. Each user must have full control over the project folder.

  • For network storage: Ensure every CADWorx user has Modify or Full Control NTFS permissions on the share. Read-only will cause error 6007 immediately.
  • For local drives: Run AutoCAD as Administrator (right-click → Run as Administrator) to bypass any UAC restrictions.

Common Symptoms Accompanying Error 6007

Before diving into solutions, recognize these additional signs that often appear alongside error number 6007:

  • CADWorx becomes unresponsive for 10–30 seconds before the error pops up.
  • The command line in AutoCAD shows ; error: bad argument type or ; error: no function definition.
  • The program crashes to desktop immediately after clicking "OK" on the error dialog.
  • Certain components appear as missing or "proxy objects" after the error occurs.

5. Windows User Account Control (UAC) or Anti-Virus Blocking

Overly aggressive UAC settings or real-time anti-virus scanning can temporarily lock the database file when CADWorx tries to access it.

3. Network Latency or File Permissions

If your CADWorx project and specs reside on a network drive (common in multi-user environments), high latency, intermittent disconnections, or insufficient read/write permissions will produce error 6007.

Overview

Error Number 6007 in CADWorx (typically associated with CADWorx Plant Professional or CADWorx Structure) generally points to a database connectivity or corruption issue. It most frequently appears when attempting to generate or update an isometric drawing, access the specification database, or create a BOM (Bill of Materials).

The exact text of the error often reads:

"Error Number 6007: [Description varies] – Unable to complete the operation. Check database connection or file integrity."

2. File In-Use (Locking)

  • The Mechanism: CADWorx specs are file-based databases. If the specification file (.MDB) is currently open in another instance of CADWorx, the Spec Editor, or Microsoft Access, the file becomes locked.
  • The Failure: A second attempt to access the spec may trigger 6007 because the application cannot obtain exclusive access to create the work file.

Troubleshooting Error Number 6007 in CADWorx: The Complete Guide

About the author

error number 6007 cadworx

Kashif

I am an Electrical Engineer. I love to write about electronics. I am passionate about writing and sharing new ideas related to emerging technologies in the field of electronics.