Gilbarco Sk700 Programming Manual Direct
Programming the Gilbarco SK700 and SK700-II dispensers involves using a manager’s keypad for basic setup parameters, such as pump type, protocol, and pricing, following a necessary "Cold Start" procedure to clear memory. Key technical procedures, including CAL switch positioning and USB configuration, are outlined in official documentation, such as the Gilbarco Installation & Commissioning Manual. For comprehensive technical instructions, reference the Kentronics SK700-2 Cold Start Guide.
Master the Gilbarco SK700: A Guide to Programming and Setup Gilbarco SK700 and its successor, the
, are staples of the modern forecourt, known for their modular design and reliability. However, whether you're performing a fresh installation or troubleshooting a system error, navigating the Programming Manual can be a challenge.
This guide breaks down the essential programming steps and command codes you need to keep your dispensers running smoothly. 1. Accessing Programming Mode
To begin programming, you must access the internal computer head. For higher-level changes (like configuration or calibration), you’ll need to interact with the Sandpiper electronics Security PINs:
Most SK700 units use standard default codes unless changed by the site manager: 2222 (Basic PPU and presets) 1503 (ID and communication settings) 1309 (Calibration and density) 0128 (Master/Cold start access) 2. Essential Command Codes The SK700 uses a Command Code system to navigate its functions. Use the Manager Keypad to enter these codes after logging in. Command Code Updates the Price Per Unit for each grade and side. Assigns the logical Pump Number for POS communication. Cold Start Clears all memory—only used for deep troubleshooting. Clock/Date Sets the dispenser's internal time and date Calibration electronic calibration of the meters. Flow Rates Adjusts the maximum liters per minute 3. Performing a "Cold Start"
If the dispenser has a major logic error or is being repurposed, a Cold Start is required to reset its memory. Safety First: Power down the dispenser. Toggle the Jumper: Locate the Cold Start jumper
on the processor board and move it to the "Cold Start" position. Reapply power. You should see a flashing on the display. Authorize: , enter the master code ( ), and select option (Clear all data).
Power down again, return the jumper to the "Normal" position, and power back up to begin initial configuration. 4. Common Troubleshooting Codes
If your dispenser stops working, look for these common error codes on the display: Pulser Disconnected—check the wiring to the meter.
Emergency Stop Button—ensure the stop button hasn't been accidentally pressed. Gilbarco Sk700 Programming Manual
POS Communication Lost—the dispenser cannot "talk" to the console.
SK700 Fuel Dispensing Overview | PDF | Corrosion | Internet - Scribd
Gilbarco SK700 programming manual is a technical document used by field service technicians to configure dispenser parameters, perform cold starts, and troubleshoot hardware. Essential Programming Codes
Programming is typically performed via the managerial keypad using specific security levels: Level 0 (0000): Basic access. Level 1 (2222): Set Price Per Unit (PPU) [Command Code 20]. Level 4 (0128): Master access for core system changes. Command Code Options/Action PPU (Price) Select Side (1, 2, or 3 for both) then Grade. Operation Mode 1 = Two-wire (remote); 2 = Standalone. Volume Allocation Set max volume limit per transaction. Pump Beeper Enable or disable the keypad/transaction beeper. Display Test Adjust segment lamp test time (default is 3s). Cold Start & Initial Setup
A cold start is required for major reconfigurations or after replacing the CPU board: Hardware Access: Open the CPU board cover. Toggle Switch: Move the switch to the CAL position. Jumper: Move the jumper to the Cold Start position. Power Up: The display will show a flashing E9.
Enter Codes: Press F1, enter master code 0128, and press Enter.
Basic Parameters: You must set the country code, pump type, pump numbers, and protocol. Troubleshooting Quick Reference Common error codes seen on the unit price display: E1 / E35: Database or configuration error. E5 / E5034: Software cold start executed. E9 / 5035: Hardware cold start jumper is active.
Code 11: Two-wire communication lost between pump and controller. Code 20: Pulser disconnected or not mapped correctly. Code 33: Emergency Stop (E-Stop) button activated.
Detailed error logs can be requested directly from Gilbarco Veeder-Root or specialized repair centers like Kentronics. If you'd like, I can:
Give you the exact steps for a specific code (like changing the PPU). Final Recommendation
Provide a deeper breakdown of error codes for a specific issue (e.g., leaks or communication failure).
Help you find a PDF version of a specific sub-manual (like for the Apollo CPU or LPG units). What is the current issue or task you are working on?
Introduction
In the fast-paced world of retail fuel dispensing, few names carry as much weight as Gilbarco Veeder-Root. Among its legacy of durable, field-proven equipment, the Gilbarco SK700 series stands out as a workhorse of the forecourt. For technicians, site owners, and service personnel, the key to unlocking the SK700’s full potential lies in one essential document: The Gilbarco SK700 Programming Manual.
This feature provides a comprehensive overview of the SK700 programming manual—its purpose, structure, key functions, and why mastering it remains critical for efficient fuel station management, even as newer models emerge.
Final Recommendation
- Keep it if you operate a site with SK700 dispensers. Photocopy the error code and calibration pages — they will save you hours.
- Don’t rely on it alone for safety compliance. Always cross-reference with NFPA 30A and current local electrical codes.
- Seek a modern supplement if you add pay-at-pump or cloud monitoring; the SK700 was not designed for serial data polling.
Bottom Line: Indispensable for maintaining SK700s, but dangerously silent on modern safety and integration practices. Use as a repair reference, not a system design guide.
Gilbarco SK700 programming instructions are typically found within the Manager Functions Manual
or specialized service guides. Programming is generally performed using a Manager Keypad
and often requires specific security codes depending on the access level required. Core Programming Codes & Access
To enter programming mode, you typically use the following master codes on the keypad: Master Code: (frequently used for Function mode/Level 4 commands). Level 2 Security Code: (used for standard parameters like pump numbers). Key Function Codes
Programming is organized by function codes. Common configurations include: Pump Numbers: Command Code 40 in Level 2. Real-Time Volume/Money: Keep it if you operate a site with SK700 dispensers
Function Code 5 (40.5 -> 1 for Money, 40.5 -> 2 for Volume). Pulse Scaling: Function Code 6 (e.g., 40.6 -> 100 for 100 Pulses/Liter). Auto Authorization: Function Code 8 (40.8 -> 1 to Enable). Slowdown Valve Settings: Command Code 88 (e.g., 88.1.1 for Side 1 Grade 1). Cold Start Procedure
A "Cold Start" is required for major configuration changes, such as changing the Country Code Preparation: Power down the unit and move the CAL switch to the "CAL" position.
Move the two-wire enable jumper to the "Cold Start" position. The display should flash , enter code , and then press to reboot. Re-Configure:
After the reboot, basic parameters like Country Code, Pump Type, and Protocol must be set. Reference Manuals Installation & Commissioning Manual: Available at Gilbarco Australia , covering setup and initial codes. Programming Guides:
Summarized versions of parameter sets are often hosted on platforms like Technical Overview: Details on electronics and hydraulics can be found in the SK700 Technical Overview or trying to resolve a particular error code on your dispenser?
3️⃣ Typical Programming Tasks – Step‑by‑Step Summaries
Below are concise, original instructions for the most common configuration changes. Follow the safety checklist first (de‑energize, wear insulated gloves, verify lock‑out/tag‑out).
4. Network & Communications
- Configure communication parameters to host, POS, or forecourt controllers:
- Protocol: TCP/IP or serial (RS-232/RS-485) depending on host.
- IP Settings: IP address, subnet mask, gateway (for TCP/IP).
- Port: TCP port number matching host.
- Serial Settings: Baud rate, parity, data bits, stop bits, and device ID.
- Set retry intervals, timeouts, and enable/disable automatic reconnect.
- For secure sites, set VPN or secure tunneling as required by site network policies.
A. Changing a Price‑Grade Table
| Step | Action |
|------|--------|
| 1️⃣ | Connect a Gilbarco service cable (DB‑9 RS‑232 or Ethernet) from the dispenser’s Service Port to your laptop. |
| 2️⃣ | Launch the SK‑H host application (often installed as SK_Host.exe). |
| 3️⃣ | Select the target dispenser from the drop‑down list (use the pump’s Serial/Asset number). |
| 4️⃣ | Backup the existing configuration: File → Export → CurrentConfig_<pump‑id>_YYYYMMDD. Store the file in a secure folder. |
| 5️⃣ | Navigate to Configuration → Grade/Price Tables. You’ll see a grid with columns: Grade Code, Price (¢/gal), Tax Code, Effective Date. |
| 6️⃣ | Edit the desired row(s). Example: Change “UNL” (Unleaded) from 2.849 ¢/L to 2.975 ¢/L. |
| 7️⃣ | Click Validate – the software checks for overlapping price‑effective dates and required tax fields. |
| 8️⃣ | Write the new configuration: File → Upload → CurrentConfig. Confirm the prompt (“Are you sure you want to write to dispenser #123?”). |
| 9️⃣ | Reboot the dispenser (soft‑reset via the host or power‑cycle the unit). |
| 🔟 | Verify on the pump screen that the new price appears, then run a Test Transaction in Service Mode to ensure the price calculation is correct. |
2. Accessing Programming Mode
- Enter installer/technician mode using the dispenser’s keypad and/or authorized key switch per site configuration.
- Typical steps:
- Turn key switch to PROGRAM or TECH position.
- On keypad, press function sequence (e.g., 1-2-3 or MENU + PIN) as set by site.
- If a PIN is required, obtain from site administrator; default PINs are often changed for security.
2️⃣ How to Get the Official Manual
| Method | How to Proceed | |--------|----------------| | Gilbarco Glen Research Customer Portal | If your site has a service contract, log in with your account → Documentation → Dispenser Manuals → SK‑700 and download the latest PDF. | | Authorized Distributor | Ask your local Gilbarco dealer for a copy; they often provide a printed manual with a service agreement. | | Technical Support | Call Gilbarco’s support line (US +1‑800‑555‑SK70, EU +44‑... ) and request “SK‑700 Programming Manual – latest revision”. You’ll be asked for a serial number or contract ID. | | On‑Site Service Engineer | If you have a service contract, the field tech will bring a copy and can walk you through the sections you need. |
Tip: Keep a copy of the revision number (e.g., “Rev 3.2 – 2024‑06”) on the pump’s nameplate. The manual’s front page will reference that same revision; using a mismatched version can cause confusion when parameter names have changed.
Chapter 2: Basic Configuration (Level 1 Programming)
This section is for site managers and covers:
- Setting the current date and time.
- Fuel grade naming (e.g., "Regular," "Premium," "Diesel").
- Price per unit (gallon or liter) – including decimal precision.
- Tax table setup (if applicable for the region).