The HPE Smart Array S100i SR Gen10 SW RAID driver for Windows Server 2022
is a software-based storage solution that enables basic data protection and performance for entry-level SATA configurations on HPE ProLiant Gen10 servers. Core Capabilities
Storage Interface: Supports up to 14 SATA lanes using 6Gb/s SATA technology.
RAID Levels: Supports standard entry-level configurations, including RAID 0, 1, 5, and 10.
Drive Support: Manages up to 14 physical drives and up to 14 logical drives.
Platform Compatibility: Specifically designed for embedded SATA ports on HPE ProLiant Gen10 servers and HPE Synergy Gen10 compute modules. Data Protection & Reliability
Predictive Drive Failure: Detects potential issues before they occur, allowing for proactive component replacement.
Background Surface Scan: Checks drives during inactive periods to automatically remap bad sectors and maintain data integrity.
HPE SmartSSD Wear Gauge: Monitors and reports the remaining lifetime of installed SSDs.
Event Notification Service: Integrates with the Windows Server system event log to provide real-time status updates. Deployment Requirements
Boot Mode: Operates exclusively in UEFI Boot Mode; it is not supported in Legacy BIOS Mode.
Installation: The driver is not included in standard Windows Server media. It must be manually injected during OS installation via USB or automatically added using HPE Intelligent Provisioning.
Updates: It is highly recommended to use the latest driver version (e.g., v1010.14.0.0 or later) available through the HPE Support Center to ensure stability on Windows Server 2022.
The HPE Smart Array S100i SR Gen10 SW RAID is fully supported on Windows Server 2022. Because this is a software-based (driver-based) RAID solution, the device driver is not included in the standard Microsoft Windows installation media; you must manually provide it during the OS installation process for the installer to recognize your logical volumes. Key Driver Information
Latest Driver Version: 1010.14.0.0(C) (or newer) is the specific version released to support Windows Server 2022.
Official Source: You can download the verified driver directly from the HPE Support Center.
Required Action: A system reboot is required after installation for the updates to take effect and maintain hardware stability. How to Install During Windows Setup
If you are installing Windows Server 2022 onto a drive managed by the S100i, follow these steps:
Extract the Driver: Download the .exe driver package from HPE and extract the contents (using a tool like 7-Zip) to a USB flash drive.
Load Driver: During the "Where do you want to install Windows?" screen, click Load Driver.
Browse: Insert your USB drive, browse to the folder where you extracted the files, and select the appropriate driver file.
Alternative (Assisted): Use HPE Intelligent Provisioning to automate the OS installation; this method automatically injects the necessary S100i drivers for you. S100i SR Gen10 Features RAID Levels: Supports RAID 0, 1, 5, and 10. The HPE Smart Array S100i SR Gen10 SW
Capacity: Manages up to 14 SATA drives connected to the system board's embedded SATA ports.
Limitation: This "S-class" controller is strictly supported on Windows only; it does not support Linux or VMware in RAID mode (these OSs must use AHCI mode).
If you're having trouble with the drives appearing even after loading the driver, let me know your server model (e.g., DL360 Gen10) and whether you've already configured the RAID array in the UEFI System Utilities.
This is a detailed guide on how to deploy the HPE Smart Array S100i sr Gen10 Software RAID driver on Windows Server 2022.
The HPE Smart Array S100i SR Gen10 SW RAID driver for Windows Server 2022 is not optional—it is mandatory. Without it, your server’s storage is invisible to the OS. By following this guide, you can:
ssacli and regular firmware updates.Whether you are deploying a single ProLiant DL20 Gen10 for a branch office or a fleet of DL380 Gen10 servers, mastering the S100i driver saves hours of deployment headaches. Remember: In the world of HPE Gen10 software RAID, the driver is the bridge between your hardware and the operating system. Use the correct one, and Windows Server 2022 will run reliably. Ignore it, and you’ll find yourself staring at an empty disk selection screen.
HPE Official Resources:
Have questions about integrating the S100i driver into a Windows Server 2022 unattended installation (answer file)? Or need help converting an existing AHCI installation to S100i RAID without data loss? Leave a comment below—or consult HPE’s official support forums for advanced scripting examples.
Last updated: October 2025
Applies to: HPE ProLiant Gen10, Gen10 Plus, Windows Server 2022 Standard/Datacenter, S100i SR Gen10
The HPE Smart Array S100i SR Gen10 SW RAID Driver for Windows Server 2022 is a critical software-based RAID driver required for Windows to recognize logical drives managed by the embedded S100i controller on HPE ProLiant Gen10 servers. Download Information Latest Driver Version: 1010.14.0.0(C). Release Date: September 28, 2022.
Official Support Page: HPE Support Center - S100i Driver for Windows Server 2022.
Alternative Support: For Gen10 Plus systems, use the HPE Smart Storage SR100i Gen10 Plus SW RAID Driver. Important Prerequisites
Driver Exclusion: This driver is not included in the standard Microsoft Windows OS media.
RAID Configuration: You must first create your RAID array (RAID 0, 1, 5, or 10) in the UEFI System Utilities (F9) or HPE Smart Storage Administrator (F10) before starting the OS installation.
UEFI Mode: The S100i controller requires the server to be in UEFI Boot Mode; it does not support Legacy BIOS mode. Installation Methods 1. Assisted Installation (Recommended)
Use HPE Intelligent Provisioning (press F10 during boot). This method automatically injects the necessary S100i drivers into the Windows Server 2022 installation process, so no manual driver loading is required. 2. Manual Injection (During Windows Setup) If you are installing Windows directly from a USB or ISO:
The HPE Smart Array S100i SR Gen10 SW RAID is a driver-based storage solution for HPE ProLiant Gen10 servers. It supports RAID levels 0, 1, 5, and 10 for up to 14 SATA drives. Because it is a software RAID, its driver is not included in standard Windows Server 2022 installation media; you must manually provide it during setup for Windows to "see" your logical drives. 1. Official Driver Download
HPE provides a specific version of this driver for Windows Server 2022. Version: 1010.14.0.0(C) Release Date: September 28, 2022
Direct Source: Download the HPE Smart Array S100i SR Gen10 SW RAID Driver from the HPE Support Center. 2. Pre-Installation Configuration
Before installing the OS, the controller must be set to RAID mode and an array must be created.
Enable RAID Mode: During POST, press F9 to enter UEFI System Utilities. Navigate to System Configuration > BIOS/Platform Configuration (RBSU) > Storage Options > SATA Controller Options > Embedded SATA Configuration and select Smart Array SW RAID Support. Identify whether your server uses S100i (check F9
Create Array: Enter the HPE Smart Storage Administrator (SSA) (usually via F10 Intelligent Provisioning or F9 System Configuration) to create your RAID volume. 3. OS Installation Steps
If you are not using HPE Intelligent Provisioning (which automatically injects drivers), follow these manual steps:
Extract the Driver: Download the .exe driver file. Run it on another PC and select the option to Extract the files to a USB flash drive. Load Driver During Setup: Boot from the Windows Server 2022 media.
When the "Where do you want to install Windows?" screen appears (and no disks are listed), click Load driver.
Browse to the folder on your USB drive where you extracted the driver files.
Select the HPE Smart Array S100i SR Gen10 SW RAID driver. Once loaded, your RAID logical drive should appear in the list. 4. Key Specifications
Compatibility: Exclusively for Windows environments; Linux and VMware require different configurations or are not supported in SW RAID mode. Interface: 6Gb/s SATA.
CPU Impact: As a software RAID, it utilizes system CPU for RAID calculations, though performance tests on Windows Server 2022 show minimal CPU load differences between entry-level and high-end processors.
The HPE Smart Array S100i SR Gen10 SW RAID is an embedded, driver-based SATA RAID solution for HPE ProLiant Gen10 servers. While originally designed for older Windows versions, it is fully supported on Windows Server 2022 through specific driver releases. Critical Driver Information
To ensure Windows Server 2022 recognizes your RAID volumes during or after installation, you must use the correct driver version.
Recommended Version: 1010.14.0.0(C) (or later) is the dedicated release for Windows Server 2022.
Alternative Support: Older versions like 106.12.6.0(D), primarily for Server 2019, have also been reported to load successfully on Server 2022.
Official Download: You can find the latest package on the HPE Support Center. Technical Capabilities & Limitations
The S100i is a "Software RAID" (S-class) controller, meaning it relies on the server's CPU to manage RAID logic.
The official driver for the HPE Smart Array S100i SR Gen10 SW RAID
on Windows Server 2022 is version 1010.14.0.0(C), released by HPE on September 28, 2022. Driver Details Version: 1010.14.0.0(C) Release Date: September 28, 2022
File Name: Typically provided as an executable (e.g., cp052316.exe) which must be extracted for manual installation.
Official Download: HPE Support Center - S100i Driver for Windows Server 2022. Installation Methods
The S100i driver is not included in standard Windows Server 2022 installation media. Use one of these methods to ensure your drives are recognized:
Intelligent Provisioning (Recommended): Use the assisted installation option in HPE Intelligent Provisioning. This automatically injects the required drivers during the OS setup. Manual Injection:
Download the driver and run the .exe on a separate PC to extract the files to a USB drive. Whether you are deploying a single ProLiant DL20
During the Windows "Where do you want to install Windows?" screen, click Load Driver and point to the folder on your USB drive.
iLO Remote Console: You can mount the driver folder as a virtual USB key using the HTML5 Remote Console in iLO for easier access during remote installs. Critical Technical Notes UEFI Only: The
requires the server to be in UEFI Boot Mode. It does not support Legacy BIOS mode.
SATA Only: This controller only supports SATA drives (up to 14 lanes) and basic RAID levels 0, 1, 5, and 10.
Performance: As a software-based RAID solution, it relies on the Windows driver to manage the array. Performance is generally lower than dedicated hardware RAID controllers (like the P-class Smart Array) and may not scale with high-end CPU upgrades.
Gen10 Plus Warning: If you are using a Gen10 Plus server, you likely need the SR100i Gen10 Plus driver instead, which is version 1010.124.100.1005.
As of 2025–2026, HPE provides native Windows Server 2022 drivers for the S100i controller. They are not built into the Windows Server 2022 installation media by default, meaning you must load them manually during OS installation or add them post-deployment.
The HPE Smart Array S100i SR Gen10 is fully supported on Windows Server 2022, but it requires a specific deployment workflow compared to hardware RAID controllers. The use of HPE Intelligent Provisioning is the most reliable method for ensuring driver compatibility and system stability. System administrators should avoid "naked" installs of Windows Server 2022 without first preparing the S100i driver package, as the default Windows media does not include the necessary HPE proprietary drivers for this software-defined storage controller.
References:
HPE Smart Array S100i SR Gen10 SW RAID is an entry-level software RAID solution that supports Windows Server 2022 through specific driver versions. Hewlett Packard Enterprise Essential Documentation
For comprehensive technical details and step-by-step setup, refer to these primary HPE resources: HPE Smart Array S100i SR Gen10 QuickSpecs
: Provides the official overview of supported features, including RAID levels 0, 1, 5, and 10 for up to 14 SATA drives. HPE Smart Array SR Gen10 User Guide
: Detailed technical manual covering configuration, management via HPE Smart Storage Administrator (SSA), and troubleshooting. Hitachi Global Driver & Installation Requirements
To use this controller with Windows Server 2022, ensure you meet the following criteria: Driver Version : Use version 1010.14.0.0(C)
or later, which explicitly adds support for Windows Server 2022. You can download it directly from the HPE Support Center : The S100i controller requires the system to be in UEFI Boot Mode ; it is not supported in Legacy BIOS mode. SATA Configuration : The embedded SATA ports must be set to Smart Array SW RAID Support in the UEFI System Utilities ( Storage Options SATA Controller Options Installation Tip
: If you are installing Windows Server 2022 from scratch, you must manually inject the driver
during the "Where do you want to install Windows?" step for the logical drives to appear. Hewlett Packard Enterprise Key Performance & Support Considerations Software-Based
: As a "S-class" controller, RAID calculations are performed by the system CPU rather than dedicated hardware. RAID Limitation
: It is a "RAID-only" controller, meaning physical drives are masked from the OS and can only be seen once a logical volume is created. OS Compatibility
If you are installing a fresh copy of Windows Server 2022, this is the standard method. Without this driver, the Windows installer will not see any hard drives.
.inf file.The system will load the driver, and after a few seconds, your configured logical RAID volume(s) should appear.
.exe file on a working Windows PC (or use 7-Zip on the .exe).D:\S100i_Driver\)..inf, .sys, and .cat files. For the S100i, look for a structure like:\Driver\Win2022\amd64\HPE Smart Array S100i SR Gen10 SW RAID Drivercp048234.exe or similar).Alternative direct search (if you have HPE Passport):
Search for “S100i Windows Server 2022 driver” → filter by OS.