Summary
Conclusion
The Merlin Gerin Multi 9 IC 2000 P is a programmable twilight switch that combines light sensitivity with a time clock to control electrical loads based on both ambient brightness and specific schedules. Key Technical Specifications Brightness Range: Adjustable from 2 to 2000 lux.
Load Capacity: Directly controls up to 1000W for incandescent or halogen lamps; use with a contactor for higher loads.
Time Switch: Integrated single-channel weekly programmer with a 10-year battery reserve. Programming: Allows up to 56 switching operations. Installation and Wiring
Mounting: The device is designed for DIN rail installation (standard 18mm modules).
Sensor Placement: Install the supplied outdoor wall-mounted sensor away from artificial light sources (like streetlights) that might trick the system. Wiring Connections: Terminals L & N: Main power supply (220-240V AC).
Terminals 3 & 5: Photocell sensor connection (maximum distance of 100m). Terminals 2 & 4: Output contact to the load or contactor. Programming Guide
The IC 2000 P uses a menu-driven interface to set parameters:
Initial Setup: Select your language and set the current date and time. Operating Programs:
DAYPROG: Lights active between 07:00 and 20:00 if the lux threshold is met. NIGHTPROG: Active between 05:00–08:00 and 18:00–23:00.
EMPTYPROG: No pre-set time validation; relies purely on light level or custom times.
Setting the Threshold: Use the + and - keys to set your desired lux level. A bar graph on the display shows current brightness relative to your setting. Merlin Gerin Multi 9 Ic 2000 P Manual
Summer/Winter Time: To adjust for daylight savings, press the dedicated button combinations (usually a simultaneous press of two keys as shown in the Operating Instructions). Troubleshooting and Maintenance
Reset: To clear all programs and dates, hold the reset buttons simultaneously for a few seconds.
Frequent Tripping: If the device switches off unexpectedly, check for light reflections hitting the sensor or an electrical overload in the circuit.
Battery: The internal battery recharges automatically when power is connected.
For the most recent version of this guide, refer to the Schneider Electric Support Portal (Schneider Electric acquired the Merlin Gerin brand).
The Merlin Gerin Multi 9 IC 2000 P is a DIN-rail mounted, programmable twilight switch that manages lighting based on ambient light levels (2-2000 lux) and 7-day schedules. It operates on 230V AC, offers adjustable time delays to prevent flickering, and features a 16A dry contact output. For the full operating instructions, visit Schneider Electric
Manual Merlin Gerin IC2000P (page 1 of 2) (English) - Libble.eu
Merlin Gerin Multi 9 IC 2000 P Guide The Merlin Gerin (Schneider Electric) Multi 9 IC 2000 P is a high-performance twilight switch. It automatically manages lighting based on ambient light levels. 💡 Key Specifications Light Range: 2 to 2000 Lux.
Time Delay: Adjustable (approx. 20–80 seconds) to prevent flickering. Output: 16A switching capacity. Mounting: Standard DIN rail. 🔧 Wiring Setup
Safety first: Always turn off the power before installation.
Power Supply: Connect phase and neutral to the designated input terminals.
External Sensor: Connect the photo-electric cell to terminals 1 and 2. Evaluation of the Merlin Gerin Multi 9 IC
Load: Connect your lights to the output relay (terminals 3 and 5). ⚙️ Adjustment & Calibration The unit features two main dials on the front face:
Lux Threshold: Set the light level where the switch triggers. Lower Lux: Turns on later (near total darkness). Higher Lux: Turns on earlier (dusk/overcast). Status LED: Green: Power is on.
Red: Light level is below the threshold (lights should be ON). ⚠️ Common Troubleshooting
Lights flickering: Increase the lux threshold or check the sensor placement.
Never turns off: The sensor may be in a permanent shadow or dirty.
Never turns on: Check the wiring to the photo-cell or ensure the lux dial isn't set too low. If you’d like, I can help you: Find the exact wiring diagram for your specific model.
Compare it to modern Schneider alternatives if you're looking to upgrade. Troubleshoot specific error behaviors you're seeing.
Merlin Gerin Multi 9 IC 2000 P is a specialized programmable light-sensitive (twilight) switch designed to manage lighting systems based on both ambient light levels and specific time schedules. It is part of the Multi 9 modular range, typically mounted on standard DIN rails in electrical distribution boards. www.electricline.ru Core Functionality
The IC 2000 P operates by combining two control logic parameters to activate or deactivate a circuit: www.electricline.ru Brightness (IC Function):
Uses an external photocell sensor to detect ambient light. If the brightness falls below a user-defined threshold, the device prepares to trigger. Time (IH Function):
Features a built-in programmable time switch. The circuit only activates if both the light is low enough
the current time falls within an allowed "ON" period programmed by the user. RS-online.com Key Technical Specifications Brightness Threshold: Adjustable from 2 to 2,000 lux. Programming Capacity: Scope and organization
Includes 42 memory settings for a 7-day (weekly) cycle with a minimum interval of 1 minute. Power Supply: Standard 230 V AC (+10% / -15%) at 50/60 Hz. Switching Capacity:
Maximum 10 A at 250 V AC (for pf = 0.6) or 16 A (for pf = 1). Time Delay:
Built-in delay (approx. 40–80 seconds) for switching on and off to prevent "hunting" or flickering due to temporary light changes like car headlights or clouds.
Back-lit LCD screen showing time, day, output status, and operating mode. RS-online.com Operating Modes & Navigation
The device front panel features several buttons for manual control and configuration: www.electricline.ru
Used to select between "AUTO" (standard operation), "PROG" (programming), and "MAN" (manual/holiday overrides). "+" and "-": Navigation and value setting keys. Confirmation key for flashing info.
Simultaneous press of "-", "menu", and "ok" resets the unit. Manual Override:
Allows for forced "ON" or "OFF" states regardless of current sensor or time settings. RS-online.com Maintenance & Manual Access light sensitive switches IC200, IC2000, IC2000P
technical data. # light detection part: same as IC2000. # brightness threshold: adjustable from 2 to. 200 lux. # time switch part: RS-online.com
The IC2000 P is part of the Multi 9 system, meaning it clips onto a standard DIN rail. However, do not pair an old IC2000 P with modern Schneider Acti9 devices without checking selectivity. The manual recommends using VISI-SAFE lockout adapters for maintenance.
Schneider Electric no longer hosts older Multi 9 manuals directly on their main product pages, but you can still obtain them:
XX with your language code):
https://download.schneider-electric.com/files?p_File_Name=Multi9_IC2000_Manual_EN.pdfWhile installing an RCD seems straightforward, the Multi 9 IC2000 P has specific nuances:
Summary
Conclusion
The Merlin Gerin Multi 9 IC 2000 P is a programmable twilight switch that combines light sensitivity with a time clock to control electrical loads based on both ambient brightness and specific schedules. Key Technical Specifications Brightness Range: Adjustable from 2 to 2000 lux.
Load Capacity: Directly controls up to 1000W for incandescent or halogen lamps; use with a contactor for higher loads.
Time Switch: Integrated single-channel weekly programmer with a 10-year battery reserve. Programming: Allows up to 56 switching operations. Installation and Wiring
Mounting: The device is designed for DIN rail installation (standard 18mm modules).
Sensor Placement: Install the supplied outdoor wall-mounted sensor away from artificial light sources (like streetlights) that might trick the system. Wiring Connections: Terminals L & N: Main power supply (220-240V AC).
Terminals 3 & 5: Photocell sensor connection (maximum distance of 100m). Terminals 2 & 4: Output contact to the load or contactor. Programming Guide
The IC 2000 P uses a menu-driven interface to set parameters:
Initial Setup: Select your language and set the current date and time. Operating Programs:
DAYPROG: Lights active between 07:00 and 20:00 if the lux threshold is met. NIGHTPROG: Active between 05:00–08:00 and 18:00–23:00.
EMPTYPROG: No pre-set time validation; relies purely on light level or custom times.
Setting the Threshold: Use the + and - keys to set your desired lux level. A bar graph on the display shows current brightness relative to your setting.
Summer/Winter Time: To adjust for daylight savings, press the dedicated button combinations (usually a simultaneous press of two keys as shown in the Operating Instructions). Troubleshooting and Maintenance
Reset: To clear all programs and dates, hold the reset buttons simultaneously for a few seconds.
Frequent Tripping: If the device switches off unexpectedly, check for light reflections hitting the sensor or an electrical overload in the circuit.
Battery: The internal battery recharges automatically when power is connected.
For the most recent version of this guide, refer to the Schneider Electric Support Portal (Schneider Electric acquired the Merlin Gerin brand).
The Merlin Gerin Multi 9 IC 2000 P is a DIN-rail mounted, programmable twilight switch that manages lighting based on ambient light levels (2-2000 lux) and 7-day schedules. It operates on 230V AC, offers adjustable time delays to prevent flickering, and features a 16A dry contact output. For the full operating instructions, visit Schneider Electric
Manual Merlin Gerin IC2000P (page 1 of 2) (English) - Libble.eu
Merlin Gerin Multi 9 IC 2000 P Guide The Merlin Gerin (Schneider Electric) Multi 9 IC 2000 P is a high-performance twilight switch. It automatically manages lighting based on ambient light levels. 💡 Key Specifications Light Range: 2 to 2000 Lux.
Time Delay: Adjustable (approx. 20–80 seconds) to prevent flickering. Output: 16A switching capacity. Mounting: Standard DIN rail. 🔧 Wiring Setup
Safety first: Always turn off the power before installation.
Power Supply: Connect phase and neutral to the designated input terminals.
External Sensor: Connect the photo-electric cell to terminals 1 and 2.
Load: Connect your lights to the output relay (terminals 3 and 5). ⚙️ Adjustment & Calibration The unit features two main dials on the front face:
Lux Threshold: Set the light level where the switch triggers. Lower Lux: Turns on later (near total darkness). Higher Lux: Turns on earlier (dusk/overcast). Status LED: Green: Power is on.
Red: Light level is below the threshold (lights should be ON). ⚠️ Common Troubleshooting
Lights flickering: Increase the lux threshold or check the sensor placement.
Never turns off: The sensor may be in a permanent shadow or dirty.
Never turns on: Check the wiring to the photo-cell or ensure the lux dial isn't set too low. If you’d like, I can help you: Find the exact wiring diagram for your specific model.
Compare it to modern Schneider alternatives if you're looking to upgrade. Troubleshoot specific error behaviors you're seeing.
Merlin Gerin Multi 9 IC 2000 P is a specialized programmable light-sensitive (twilight) switch designed to manage lighting systems based on both ambient light levels and specific time schedules. It is part of the Multi 9 modular range, typically mounted on standard DIN rails in electrical distribution boards. www.electricline.ru Core Functionality
The IC 2000 P operates by combining two control logic parameters to activate or deactivate a circuit: www.electricline.ru Brightness (IC Function):
Uses an external photocell sensor to detect ambient light. If the brightness falls below a user-defined threshold, the device prepares to trigger. Time (IH Function):
Features a built-in programmable time switch. The circuit only activates if both the light is low enough
the current time falls within an allowed "ON" period programmed by the user. RS-online.com Key Technical Specifications Brightness Threshold: Adjustable from 2 to 2,000 lux. Programming Capacity:
Includes 42 memory settings for a 7-day (weekly) cycle with a minimum interval of 1 minute. Power Supply: Standard 230 V AC (+10% / -15%) at 50/60 Hz. Switching Capacity:
Maximum 10 A at 250 V AC (for pf = 0.6) or 16 A (for pf = 1). Time Delay:
Built-in delay (approx. 40–80 seconds) for switching on and off to prevent "hunting" or flickering due to temporary light changes like car headlights or clouds.
Back-lit LCD screen showing time, day, output status, and operating mode. RS-online.com Operating Modes & Navigation
The device front panel features several buttons for manual control and configuration: www.electricline.ru
Used to select between "AUTO" (standard operation), "PROG" (programming), and "MAN" (manual/holiday overrides). "+" and "-": Navigation and value setting keys. Confirmation key for flashing info.
Simultaneous press of "-", "menu", and "ok" resets the unit. Manual Override:
Allows for forced "ON" or "OFF" states regardless of current sensor or time settings. RS-online.com Maintenance & Manual Access light sensitive switches IC200, IC2000, IC2000P
technical data. # light detection part: same as IC2000. # brightness threshold: adjustable from 2 to. 200 lux. # time switch part: RS-online.com
The IC2000 P is part of the Multi 9 system, meaning it clips onto a standard DIN rail. However, do not pair an old IC2000 P with modern Schneider Acti9 devices without checking selectivity. The manual recommends using VISI-SAFE lockout adapters for maintenance.
Schneider Electric no longer hosts older Multi 9 manuals directly on their main product pages, but you can still obtain them:
XX with your language code):
https://download.schneider-electric.com/files?p_File_Name=Multi9_IC2000_Manual_EN.pdfWhile installing an RCD seems straightforward, the Multi 9 IC2000 P has specific nuances: