The Nalco Ultimer 7752 Safety Data Sheet (SDS) outlines the physical and chemical properties of a specialized water-based polymer used for industrial wastewater treatment. Designed to improve the capture efficiency of solids and facilitate water reuse, the "new" or latest versions of this SDS prioritize environmental sustainability by highlighting the product's lack of hydrocarbon solvents and volatile organic compounds (VOCs). Chemical Identity and Physical Properties
Nalco Ultimer 7752 is a liquid polymer typically used as a flocculant in primary and secondary wastewater treatment. Key physical characteristics listed in the SDS include: Appearance: White liquid. Odor: Chlorine-like or negligible.
pH Level: Ranges from 3.0 to 4.1 at 100% concentration, indicating an acidic nature. Solubility: Fully miscible in water. Boiling Point: Approximately 100∘C100 raised to the composed with power C 212∘F212 raised to the composed with power F
Flammability: Not flammable or combustible; it does not have a flash point under standard conditions. Safety Hazards and First Aid
While modern Ultimer technology is designed to be safer than traditional latex-based flocculants, standard safety protocols remain essential.
Health Hazards: Under normal use, health injuries are generally not expected or known. It is not currently classified as a hazardous chemical by major standards like OSHA. First Aid Measures: Eye Contact: Flush with water immediately. Skin Contact: Wash the affected area with soap and water.
Inhalation: Move to fresh air; symptomatic treatment is usually sufficient.
Firefighting: Since it is non-flammable, standard extinguishing media like water spray or foam are appropriate for surrounding fires. Environmental Impact and Handling
One of the primary benefits highlighted in the latest Nalco Ultimer documentation is its reduced environmental footprint.
Sustainability: Unlike older emulsion flocculants, Ultimer 7752 does not contain oils or surfactants, which significantly reduces VOC emissions and hazardous waste output.
Storage: Should be stored in labeled, tightly closed containers away from heat sources and oxidizers.
Disposal: While not inherently hazardous waste, it must be disposed of according to local, state, and federal regulations. ULTIMER Polymer Technology | Ecolab
Nalco ULTIMER® 7752 is a water-based polymer technology used primarily for wastewater management and water clarification . According to the Safety Data Sheet (SDS), it is generally not classified as a hazardous substance under normal use. 1. Product Identification & Properties Product Name: ULTIMER® 7752 Physical Form: White liquid Chlorine-like Flash Point: > 93.3°C (Non-flammable/Non-combustible) 3.0 – 4.1 (at 100%, 25°C) Freezing Point: Pour point of -5°C www.farnese.co.nz 2. Safety & Handling Precautions
While not classified as hazardous, standard industrial hygiene is required: Eye & Skin Protection: nalco ultimer 7752 msds new
Wear safety glasses and protective clothing. Although health injuries are not expected, it is best to avoid direct contact.
Wash face and hands thoroughly after handling. Remove and wash any contaminated clothing before reuse. Slippage Hazard:
Like many polymers, this product may become extremely slippery when wet. Ensure surfaces are washed thoroughly if spilled. 3. First Aid Measures
If exposure occurs, follow these steps and seek medical advice if symptoms persist: Rinse immediately with plenty of water. Wash off with soap and plenty of water. Ingestion: Rinse mouth. Do induce vomiting unless directed by medical personnel. Inhalation:
Move to fresh air; seek medical attention if symptoms develop. 4. Firefighting & Spill Control Extinguishing Media:
Use media appropriate for the surrounding environment (e.g., dry chemical, foam, or water spray).
Stop the leak if safe. Contain with non-combustible absorbent material (sand or earth) and place in a labeled container for disposal. Do not allow the product to reach soil or waterways. Hazardous Combustion:
May release carbon, nitrogen, and sulfur oxides, or hydrogen chloride under fire conditions. 5. Storage & Disposal
Keep containers tightly closed in a dry, well-ventilated area. Protect from frost and extreme temperatures to prevent viscosity changes or pumping issues.
Dispose of fire residues and contaminated water in accordance with local and national regulations.
For the most current or site-specific version, you can request an official SDS directly through the Ecolab SDS portal in oily wastewater or specific pumping requirements for low temperatures? ULTIMER® 7752 Safety Data Sheet | PDF | Toxicity - Scribd
Nalco Ultimer 7752 is a specialized water-based polymer technology developed by Nalco Water (an Ecolab company) primarily for industrial wastewater treatment. Unlike traditional emulsion flocculants, it is part of the Ultimer product line, which is designed to be solvent-free and environmentally friendly.
The following article provides a detailed overview of the product based on the latest Safety Data Sheet (SDS) information. Product Overview and Application The Nalco Ultimer 7752 Safety Data Sheet (SDS)
Ultimer 7752 is a cationic dispersion flocculant. It is widely used in primary wastewater treatment to enhance the removal of suspended solids. Common applications include:
Wet Gas Scrubbers: Improving solids capture efficiency in refinery operations.
Oily Wastewater: Maintaining performance in highly variable or oily industrial streams.
Water Reuse: Enabling the recycling of process water by ensuring consistent effluent quality. Physical and Chemical Properties
According to technical specifications, Ultimer 7752 has the following characteristics: Appearance: White liquid. Odour: Slight chlorine-like scent. pH Level: 3.0 – 4.1 (100% concentration). Boiling Point: Approximately 100°C.
Flash Point: > 93.3°C (Pensky-Martens closed cup method), indicating it is not classified as flammable under standard conditions. Solubility: Dispersible in water. Safety and Hazards Information
While Ultimer technology is designed to reduce the use of hazardous hydrocarbon solvents, it still requires careful handling. Based on common SDS classifications for this product group:
Potential Health Effects: May cause mild skin and eye irritation upon direct contact. Inhalation of mists or vapors may irritate the respiratory tract.
Environmental Impact: While the product itself aims for sustainability, concentrated spills can be toxic to aquatic life. For example, similar formulations show toxicity to rainbow trout (LC50 values).
Firefighting: The product is not flammable, but if involved in a fire, decomposition can release carbon oxides, nitrogen oxides, and hydrogen chloride. Use dry chemical, foam, or water spray for surrounding fires. Handling, Storage, and First Aid
Proper industrial hygiene is essential when working with Nalco chemicals. ULTIMER Polymer Technology | Ecolab
NALCO ULTIMER® 7752 is a water-based liquid polymer used primarily for solids capture in wastewater treatment. According to the Safety Data Sheet (SDS), it is generally classified as non-hazardous under normal conditions of use. Summary of Safety Data Sheet (SDS)
Below are the key safety and physical specifications for Nalco ULTIMER 7752: Hazard Identification Official source: Ecolab / Nalco Water’s SDS portal
: Health injuries are not known or expected under normal use. Classification
: Not classified as a dangerous good or hazardous substance according to standard regulations. Physical & Chemical Properties Appearance : White liquid. : Slight chlorine-like scent. : 3.0 – 4.1 (at 100% concentration). Flash Point
: > 93.3 °C (200 °F), meaning it is not considered flammable. Solubility : Complete solubility in water. First Aid Measures Eye/Skin Contact
: Flush with water; seek medical advice if symptoms develop.
: Wash out mouth with water; do not induce vomiting without medical advice. Handling & Storage
: Keep container closed when not in use; avoid overheating to prevent thermal decomposition.
: Wear suitable gloves and eye/face protection (safety goggles) during handling. Manufacturer Support
Ecolab (Nalco Water) does not always provide full SDS documents for public download. For the most recent 2024–2026 version or specific regional compliance documents, you should use official channels: SDS Request Form Nalco Water SDS Request Form to receive the latest version via email. Official Search : Check the Ecolab SDS Search by entering "7752" or the specific product code. Direct Contact
: For emergencies, refer to the telephone numbers listed on your specific product label or contact their customer service. files.dep.state.pa.us technical performance data for ULTIMER 7752 in specific wastewater applications? ULTIMER® 7752 Safety Data Sheet | PDF | Toxicity - Scribd
Using an outdated MSDS (pre-2015 or pre-GHS) is a regulatory violation under OSHA's Hazard Communication Standard (29 CFR 1910.1200) in the US, and under CLP Regulation (EC) No 1272/2008 in Europe.
The new MSDS is stricter here, moving from "gloves recommended" to mandatory specifications.
If you report under EPA or EU chemical regulations, note that the new SDS includes updated ecotoxicity data:
Еще нет аккаунта?
Создать аккаунт