Owon Hds2102s Firmware Update -
Updating the firmware on your OWON HDS2102S handheld oscilloscope can resolve known display discrepancies—such as incorrect horizontal graticule spacing at high speeds (2ns/div)—and improve overall measurement accuracy. Preparation Identify Current Version : On your device, press F2 (System)
, and navigate to the next page to view the current firmware version. Download Official Files : Visit the OWON Download Center and select the HDS200 Series HDS2102(S) model to download the latest update package. Verify Hardware Compatibility
: OWON updates are often dedicated to specific hardware revisions (e.g., V1 vs V2); ensure you enter your specific version number if prompted on the site. Update Steps Enable Mass Storage Mode Turn on the scope and press
On the second page of the system menu, select the USB mode as (Mass Storage Class). Connect to PC
Connect the device to your computer via a USB cable. It should appear as a removable disk (e.g., "H: drive"). Transfer Firmware Copy the downloaded firmware file (typically named ) directly to the root of the removable disk. Execute Flashing Turn the oscilloscope
The device will automatically recognize the file, begin the upgrade process, and typically power itself off once finished. Verify Update Power the device back on and check the menu to confirm the version number has changed. Alternative Method (Bootloader Mode)
If the "MSC" method is unavailable, some versions require a dedicated Update Tool Download the Firmware Upgrade Tool Owon Software page Install the necessary USB drivers on your PC.
Connect the scope, run the tool, and toggle the power to enter bootloader mode for flashing.
Do not disconnect the USB cable or power off the device manually during the flashing process, as this can brick the hardware. latest known stable version number for your hardware revision?
Updating the Owon HDS2102S firmware requires matching the software to your device's specific hardware version, as newer units may ship with versions (e.g., V4.3.0) that appear "newer" than those available on official download portals (e.g., V1.5.1). Latest Firmware Status Official Version : V1.5.1 is the most widely documented stable update on the Owon Download Center
: Version 1.51 reportedly fixes a display discrepancy at the horizontal range where graticules were incorrectly spaced. Hardware Conflicts : Users have reported receiving new units with ; experts advise against downgrading owon hds2102s firmware update
these to V1.5.1, as different hardware revisions (specifically flash chip changes) may be incompatible. Update Procedures
There are two primary methods depending on the firmware file type provided by Owon Support Method 1: USB Drive (Using .upp files) Preparation : Format a USB drive and copy the file into a folder named (if required by your version). Device Setup : Turn on the scope, press F2 (System) Connection : Set USB mode to
(Mass Storage Class) to connect to a PC, or insert the drive directly if using an adapter.
: Power cycle the device. The scope should detect the file, perform the upgrade, and shut down automatically. Method 2: PC Launcher (Using .exe tools) Connection : Connect the scope to a PC via USB cable. Launcher.exe update tool and select your language. Bootloader Mode
: Click the update button in the software, then turn the scope off and back on to enter bootloader mode for flashing. Verification : Once finished, check the version number in the Important Precautions Check Serial Number
: Firmware updates for the HDS series are often tied to specific serial number ranges (e.g., 2152xxx for HW 3.1). : Installing incompatible firmware can lead to an upside-down screen or a bricked device. Official Advice
: Owon support has sometimes advised users not to upgrade if a newer version is not explicitly listed for their specific serial on the website. current hardware version to see if an update is recommended for your specific unit?
Updating the firmware on the OWON HDS2102S Go to product viewer dialog for this item.
is a delicate process because OWON generally does not publish public firmware links for this specific model . Firmware is typically tied to specific hardware/serial number revisions, and using the wrong "piece" (firmware file) can brick the device . Critical Warning
Official advice from OWON support is to not upgrade unless you are experiencing a specific bug, as there is no universal "latest" version for the Updating the firmware on your OWON HDS2102S handheld
on their website . If you proceed, ensure the firmware you use matches your hardware revision exactly . Firmware Update Steps
If you have obtained the correct .upp file from OWON Support or an authorized source, follow these steps : Prepare the Device: Turn on the and navigate to System > System > (Next Page) > Upgrade.
Connect to PC: Connect the oscilloscope to your computer using a USB-C cable.
Enable MSC Mode: In the System menu, select USB and set it to MSC (Mass Storage Class). The scope will appear as a removable disk on your computer.
Transfer the File: Copy the firmware file (typically named Scope.upp) to the root directory of the removable disk.
Reboot and Flash: Safely eject the device, turn the scope off, and then turn it back on. The device will automatically detect the file, perform the upgrade, and shut down once finished.
Verify: Turn the device on and check the System menu to confirm the version number has updated. Common Firmware Versions & Fixes
Version 1.5.1: Known to fix a specific display discrepancy where graticules were incorrectly spaced at the 2ns/div time base .
Version 2.0.4: A newer update reported by some users, though specific changelogs are often not provided by the manufacturer . Troubleshooting & Support Official Downloads: You can check the OWON Download Center for any newly released software or manuals, though specific firmware is rarely listed there.
Contact Support: To get the correct firmware "piece" for your specific serial number, email OWON Support with your model name, serial number, and a photo of your current "System Info" screen. Metrics / telemetry (opt-in only)
The OWON HDS2102S is a handheld 2-channel 100 MHz oscilloscope with a built-in multimeter (DMM). Firmware updates for this model are not distributed through an automatic online updater; you must manually download and install them via USB.
Below is the full feature set and process for the HDS2102S firmware update, including prerequisites, step-by-step instructions, and what the update typically improves.
4. What a Firmware Update Typically Improves (based on past OWON updates)
| Area | Typical changes |
|------|----------------|
| Oscilloscope | – Improved trigger stability (edge, pulse, video)
– Faster waveform update rate
– Better auto-set behavior |
| Multimeter | – Corrected DC/AC voltage reading drift
– Enhanced resistance accuracy |
| UI | – Menu translation fixes
– Faster response to button presses
– Added storage format options (BMP/CSV) |
| Connectivity | – PC software (PC Link) compatibility fixes
– USB TMC stability |
| Battery | – More accurate battery level indication |
| Bug fixes | – Freeze on startup with probe attached
– Incorrect V/div readout in some ranges |
Metrics / telemetry (opt-in only)
- Number of successful updates
- Failure types and counts (checksum, timeout, device not found)
- Average update duration
- User-initiated cancellations (collect only non-identifying data; require explicit consent before upload)
Updating Firmware
-
Extract Firmware Files: If the downloaded firmware is not in a single
.binfile, ensure you have all necessary files. -
Copy Firmware to SD/USB: Place the firmware file(s) into the root directory of your prepared SD card or USB drive.
-
Insert SD/USB into HDS2102S: Insert the SD card or connect the USB drive to your Owon HDS2102S.
-
Enter Update Mode: Turn on your HDS2102S. Navigate to the "Utility" or "System" menu, and look for an option related to firmware update or upgrade. If you're unable to find it, consult your user manual.
-
Select Update Source: The device should detect the SD card/USB drive and display the firmware file(s) found. Select the appropriate file to initiate the update.
-
Confirm Update: A confirmation prompt will likely appear. Confirm that you want to proceed with the update.
-
Wait for Update to Complete: The device will now update its firmware. This process may take a few minutes. Do not power off the device during this time or remove the SD/USB.
-
Reboot: Once the update is complete, the device may automatically reboot. If not, manually restart it.
3. Prepare the USB Drive
- Use a USB flash drive (FAT32 format, 4GB–16GB recommended).
- Delete all files on the USB drive (backup if needed).
- Copy the firmware file (e.g.,
HDS2102S_Vxx.upg) to the root directory of the USB drive. - Do not rename the firmware file.
- Safely eject the USB drive.