Uniop Designer 6 Software Download Fixed Top Guide
UniOP Designer 6 is the legacy engineering software used to program and configure UniOP HMI (Human Machine Interface) operator panels. It is widely used in industrial automation for older systems that rely on serial or older fieldbus communications. 📥 Software Access and Downloads
UniOP Designer 6 is a commercial product and is not generally available for free. However, updates and support tools can be found through official and community channels:
Official Updates: Access service packs and updates via EXOR Int., though a full installation of Designer 6 must already be on your system.
Manuals: Comprehensive setup and installation instructions are available in the UniOP User's Manual from DAKOL and the EXOR Designer 6 Manual provided by AUDIN.
Community Support: Users on forums like PLCtalk.net often share insights on locating specific versions or resolving compatibility issues. 🛠️ Key Features of Designer 6
The software provides a complete development environment for HMI project management:
Project Transfer: Includes the UniDataExchanger utility for uploading and downloading projects and firmware via RS-232.
Design Tools: Features a Keypad Designer for creating custom floating keypads and a Font Editor for localized character sets.
Communication: Supports configuration for various controllers and network setups, including legacy fieldbus protocols.
Offline Mode: Allows for full project creation and configuration in a virtual environment before pushing to physical devices. ⚠️ Compatibility and Modern Alternatives
Because Designer 6 is a legacy tool, users should be aware of several technical limitations: Designer 6 - Desktop app for designing and ... - Shure
UniOP Designer 6 Software Report UniOP Designer 6 is a powerful HMI configuration tool developed by EXOR International for the entire UniOP product family. It serves as a single programming environment for diverse hardware, including text displays, graphic screens, and touch panels. 1. Official Download & Installation
The full UniOP Designer 6 package is not available for free download and must be purchased through authorized channels.
Service Packs: Official Designer Software Updates are available from EXOR Int. S.p.A. The latest service pack, v6.10.02.03, can be installed over an existing v6.01 installation.
Acquisition: To obtain the full software, users typically contact local distributors or EXOR support directly at support.it@exorint.com.
Pricing: While official list prices vary by region, third-party industrial retailers like Radwell International list the software starting at approximately $350.00. 2. Key Features & Capabilities
Designer 6 introduced several advancements for industrial and building automation:
Multilanguage Support: Integration of TrueType fonts and support for Asian (Unicode) characters for easier application translation.
Enhanced Connectivity: Includes over 200 communication drivers at no extra charge, supporting Ethernet upload/download and dual-driver communication.
Data Management: Extended access to recipe data, historical alarm lists, event buffers, and trend presentation. uniop designer 6 software download top
Graphics: Support for 64K colors on TFT displays and vector graphic capabilities (transparency and multiple layers) on compatible models like the eTOP Series 300. 3. Compatibility & Requirements
The software is primarily legacy-focused but remains essential for maintaining older hardware.
Hardware Compatibility: Fully compatible with the eTOP Series 300 (e.g., eTOP306, eTOP307) and older eTOP05, eTOP06, and eTOP10 models.
Operating Systems: While originally designed for Windows XP and Win7, users have reported success running Designer 6 on Windows 10, though a virtual machine (VM) may be required for specific legacy communication drivers.
Cabling: Uploading or downloading projects often requires specific serial cables like the CB4 (direct) or CB9 (isolated). 4. Technical Status & Obsolescence UniOP Designer 6 is now considered a legacy software.
Replacement: For modern applications, EXOR has transitioned to JMobile software and newer HMI hardware lines.
Support: Repair parts for older UniOP HMI models are increasingly scarce, making proactive migration to newer platforms a common recommendation for critical machinery.
Note: For detailed setup instructions, refer to the UniOP Designer 6 User Manual. Designer Software Updates | EXOR Int. S.p.A.
Guide to UniOP Designer 6: Software Overview and Download If you're managing industrial automation systems, you’ve likely encountered Exor UniOP
HMI panels. To program these devices, the essential tool is the UniOP Designer 6
software. This versatile development environment is the backbone for creating and managing graphical user interfaces across the entire UniOP product family. What is UniOP Designer 6?
UniOP Designer 6 is a specialized programming tool used to design screens, configure communication protocols, and manage alarms for UniOP operator panels. Key Features Include: Wide Device Compatibility:
Supports everything from simple text displays to advanced 64K color TFT touchscreens. Extensive Driver Library:
Offers access to more than 200 communication drivers for various industrial devices and PLCs. Advanced Visuals:
Supports TrueType fonts, multi-language applications (including Asian characters), and high-quality vector graphics. Enhanced Data Management:
Features improved handling for recipe data, event lists, and trend buffers. How to Download UniOP Designer 6 It is important to note that UniOP Designer 6 is not free software ; it is a commercial product that must be purchased. Full Package: The full software package must be ordered through EXOR International or their authorized distributors. Service Packs and Updates:
If you already have a version of Designer 6 installed (such as 6.01), you can download the latest Designer 6.10.02.03 service pack for free from the official EXOR Designer Software Updates Registration:
To access downloads on the official site, you may need to register for an account and confirm your language and version preferences. Technical Requirements
To ensure the software runs smoothly, your system should meet these minimum specifications: Operating System: Windows XP, 7, 8, or 10 (32-bit or 64-bit). UniOP Designer 6 is the legacy engineering software
512 MB RAM, 500 MB free disk space, and a screen resolution of at least Connectivity:
A USB port or Ethernet connection is required for downloading projects to the HMI panels. Legacy Considerations
While Designer 6 remains a staple for older systems, it is considered legacy software
. For newer hardware and more advanced features, manufacturers often recommend migrating to the modern JMobile Software Are you looking to upgrade an existing UniOP project or are you starting a new design from scratch?
Old UniOP PLC Project Update: Designer 6 (First time Poster)
The search for UniOP Designer 6 often feels like a digital archeology project. As a legacy Human Machine Interface (HMI) development tool by EXOR International
, it is a critical link for engineers maintaining older industrial machinery, yet its status as "obsolete" software makes a straightforward download a bit of a story in itself. The Software Legacy
UniOP Designer 6 was the go-to interface for building HMI applications across the entire UniOP product family, including models like the eTOP05, eTOP06, and eTOP310. It introduced advanced features for its time, such as TrueType font integration, support for Asian characters, and Ethernet project transfers. The Download Reality
If you are looking for a official download, there are two paths—and a significant warning: Official Updates: EXOR provides Service Packs (like version 6.10.02.03) directly on their support site
. However, these are strictly upgrades; you must already have the "Full Package" installed on your system to use them. The Full Version:
The full software was never released for free. It historically required a purchase from Exor International or authorized distributors. Third-Party Hazards:
Many sites promising a "free download" for Designer 6 often host misleading links or potentially harmful files. Expert forums like PLCTalk.net
are better places to seek legitimate advice from peers who might still have archived copies. Running Modern Hardware
Because Designer 6 is legacy software, it was primarily built for Windows XP or Windows 7. While some users report success on Windows 10, it often requires a Virtual Machine (VM)
to function correctly, particularly for communication drivers. The "Top" Recommendation: Upgrade For businesses relying on these older panels, experts at ControlMotive
suggest a "proactive replacement" strategy. Since spare parts for UniOP hardware are becoming scarce and the software is no longer officially supported for modern OS environments, migrating projects to the current JMobile software platform is the most reliable long-term solution. Further Exploration Designer Software Updates page at EXOR Int. S.p.A. for the latest service packs. Review the UniOP User's Manual
on AUDIN for detailed installation procedures and project configuration. Read community discussions on PLCTalk.net regarding the use of the free UniDataExchanger utility for basic project transfers. Are you trying to recover a project from an old panel, or are you looking to modify an existing application on a new computer? UniOP CP01-04 Designer 6 software - PLCTalk.net
nightline. Feb 26, 2021. Guys, it looks you can download it here: https://hiflex.nl/designer6-software. Jack. N. PLCTalk.net Designer Software Updates | EXOR Int. S.p.A.
UniOP Designer 6 is the legacy software used to program UniOP HMI panels, manufactured by EXOR International. It is essential for managing older industrial interfaces and migrating projects to modern hardware. 📥 Download and Installation Disable Driver Signature Enforcement (Crucial):
UniOP Designer 6 is not free software; it must be purchased as a full package. Once the full software is installed, you can download free service packs for updates.
Official Updates: Access the latest service packs (e.g., v6.10.02.03) at the EXOR Designer Software Updates page.
Full Version: If you do not have the base software, you must contact EXOR support or an authorized distributor to purchase a license.
Free Utility: For simple project transfers without full editing capabilities, use the UniDataExchanger tool, which is often available for free download through support channels. 🛠️ Key Features of Designer 6
Broad Compatibility: Supports the entire UniOP HMI family, including text displays, touch panels, and handheld devices.
Enhanced Visuals: Includes support for TrueType fonts, 64K colors on TFT displays, and Asian character sets.
Connectivity: Features over 200 drivers for seamless communication with various PLC brands.
Advanced Tools: Offers Ethernet upload/download, built-in simulation, and macro command execution on power-up. 💻 System Requirements & Compatibility
To run Designer 6 effectively, ensure your system meets these specifications:
OS: Windows XP, Vista, 7, 8, or 10 (32-bit/64-bit). Note that newer versions may require Windows 7 or "Compatibility Mode" for stable operation.
Hardware: 512 MB RAM, 500 MB free disk space, and an Intel Pentium 4 processor or higher.
Communication: A USB or RS-232 port for connecting to the HMI panel. A CB4 or CB9 cable is typically recommended for direct or isolated connections. ⚠️ Important Considerations
Firmware Conflicts: Avoid using a newer version of Designer to download projects to an older panel with very old firmware (e.g., v4.40), as this can cause the HMI screen to go blank.
Legacy Status: Since this is legacy software, EXOR recommends migrating to JMobile software for newer projects, which can often import older Designer (.upr) files. If you'd like, I can help you: Find the specific cable pinout for your HMI model
Provide a step-by-step guide for uploading a project from a panel Compare Designer 6 vs JMobile for your specific hardware Let me know which HMI model you are currently working with! Designer Software Updates | EXOR Int. S.p.A.
Here is the important information regarding downloading and using this software:
The Professional Installation Process
- Disable Driver Signature Enforcement (Crucial):
- Restart your PC → Advanced Startup → Disable driver signature enforcement. The USB drivers for Uniop are unsigned and will be blocked by default.
- Run as Administrator:
- Right-click
Setup_Designer6.exe→ Properties → Compatibility → Run this program in compatibility mode for Windows 7. - Check "Run as Administrator."
- Right-click
- Install Core Software:
- Accept the default installation path:
C:\Program Files (x86)\Exor\Designer6 - When prompted for the license, point to your
license.datfile or insert the USB dongle after installation.
- Accept the default installation path:
- Install the Service Pack:
- Run
Designer6_Updates.msp. This fixes a critical bug regarding Modbus TCP/IP timeouts.
- Run
- Install USB Drivers:
- Connect your Uniop panel (e.g., eX705) via USB-B cable.
- Windows will detect "Unknown Device." Manually browse to the
USB2Serfolder and install the driver.
Troubleshooting Tip: If the software crashes when opening a project, navigate to the installation folder and find Designer6.exe. Right-click → Properties → Disable fullscreen optimizations and Override high DPI scaling (set to Application).
Step 3 – Run installer
- Right-click
Setup.exe→ Run as Administrator - Follow the wizard:
- Accept license agreement
- Choose "Complete" installation (recommended)
- Leave default installation folder
C:\Program Files (x86)\Exor\Designer 6\
- Allow driver installation for USB license dongle if prompted
1. The Official Eaton Software Portal (Recommended)
Eaton (which acquired Exor’s HMI line) provides legacy software through their support portal.
- Action: Go to
eaton.com→ Support → Software & Downloads. - Search: Type "UniOP Designer 6" into the search bar.
- Result: You will likely find the final release (v6.2.38). You may need a free account (myEaton) to access legacy downloads.