Introduction
Xinjie PLC is a programmable logic controller (PLC) widely used in industrial automation applications. To communicate with a computer, the Xinjie PLC requires a USB driver to be installed on the computer. In this paper, we will guide you through the step-by-step process of installing the Xinjie PLC USB driver.
Hardware and Software Requirements
Before installing the Xinjie PLC USB driver, ensure that you have the following hardware and software:
Pre-Installation Steps
Before installing the driver, follow these pre-installation steps:
Installing the Xinjie PLC USB Driver
To install the Xinjie PLC USB driver, follow these steps: xinje plc usb driver install
Method 1: Installing using the manufacturer's installation package
Method 2: Installing using Windows Update
Verifying the Installation
After installing the driver, verify that the installation was successful:
Troubleshooting
If you encounter issues during installation, try the following troubleshooting steps:
Conclusion
In this paper, we have provided a step-by-step guide on installing the Xinjie PLC USB driver. By following these steps, you should be able to successfully install the driver and communicate with the Xinjie PLC using a computer. If you encounter any issues, refer to the troubleshooting section or contact the manufacturer's technical support.
Installing a Xinje PLC USB driver is the "handshake" that lets your PC talk to your industrial hardware. Whether you're using a direct USB cable or a USB-XC programming cable , follow this guide to bridge the gap. 1. Identify Your Cable and Controller Xinje PLCs usually connect in one of two ways: Direct USB Port: Newer models (like the ) often have a built-in USB port. USB-to-Serial Cable: Many older or slim models (XC series) require a specialized USB-XC programming cable . This cable typically uses a or similar chip to convert USB to RS232. 2. Download the Driver Do not rely on Windows to find the driver automatically. Visit the official Xinje Download Center Look for the "USB driver" "USB-to-Serial" driver under the software or tools section.
If you are using a 3rd party programming cable, you may need the CH341 driver specifically. 3. Installation Steps Disconnect the PLC:
Unplug the USB cable from your PC before starting the installation to avoid "unidentified device" errors. Run the Installer: Right-click the driver installer ( ) and select "Run as Administrator." The "Success" Check:
Once the installation finishes, plug the cable back into your PC and the PLC. Device Manager Verification: Device Manager on your Windows PC. Expand the Ports (COM & LPT) You should see "USB-SERIAL CH341 (COMx)" "Xinje USB" without any yellow warning triangles. Note the COM Port Number (e.g., COM3). 4. Configure Your Software
After the driver is "live," you must point your programming software to the right gate: (for XC series) or XINJE Config Communication Settings Serial Port Settings Select the that matched the number you saw in Device Manager. "Test Communication" to confirm the link is active. Troubleshooting Tips Driver Signature Error:
If you are on Windows 10 or 11 and the driver won't install, you might need to temporarily disable driver signature enforcement in your Windows startup settings. Cable Sequence: Introduction Xinjie PLC is a programmable logic controller
Always connect the cable to the PC first, wait for the chime, and then connect to the PLC. for your particular Xinje PLC model? Download Center - Wuxi Xinje Electric Co., Ltd.
Here’s a concise review of the Xinje PLC USB driver installation process, based on common user experiences (for models like XC, XD, XL series).
This is the most common hurdle. By default, Windows blocks unsigned drivers. XINJE drivers are often signed, but older versions may not be.
Method (Windows 10/11):
Driver installation means nothing if AutoShop cannot see it. Here’s how to link the software to the new COM port.
The XD series works best with the AutoShop programming software, which includes its own USB driver.