Tomzn — Tovpd160ec Manual Better [cracked]
TOMZN TOVPD1-60-EC is a 230V DIN rail protector that offers critical safeguards for your home's electrical system by monitoring over-voltage, under-voltage, and over-current. It is widely used in residential and commercial settings to protect sensitive electronics like AC units and pumps from damage caused by voltage fluctuations. Key Technical Specifications
button for more than 12 seconds to view the cause of the last trip. Factory Reset : Press and hold the button for more than 12 seconds. Manual On/Off
: The first button can manually toggle the load. When off, the lower display shows "oFF". 2. Core Parameter Settings (A1–A14) tomzn tovpd160ec manual better
When in the SET menu, you can cycle through the following 14 parameters: Default Value Adjustment Range Power-on delay (Initial start time) 1s – 500s Over-voltage protection threshold 230V – 300V / OFF Over-voltage recovery value 225V – 295V Over-voltage recovery delay time 1s – 500s Over-voltage trip action time 0.1s – 30s Under-voltage protection threshold 140V – 210V / OFF Under-voltage recovery value 145V – 215V Under-voltage recovery delay time 1s – 500s Under-voltage trip action time 0.1s – 30s Over-current protection threshold 1A – 63A Over-current action time 0.1s – 30s Over-current recovery delay time 1s – 500s Voltage calibration Over-current limit (continuous trips) 1 – 20 times / OFF 3. Technical Specifications
: Automatically reconnects power after a set delay once the electrical environment stabilizes. РКС Компоненти - РАДІОМАГ Operating Instructions TOMZN TOVPD1-60-EC is a 230V DIN rail protector
To modify settings, use the interface buttons (typically "SET," "UP," and "DOWN"). ellicomblob.blob.core.windows.net Enter Setup : Press and hold for 3 seconds. Navigate Settings repeatedly to cycle through parameters (A1, A2, etc.). Adjust Values arrows to change values. Factory Reset : Press and hold the button for more than 12 seconds. View Fault History : Press and hold the
button for more than 12 seconds to check the last protection event. Recommended Settings (Default vs. Range) Default Setting Adjustable Range Over-Voltage Trip 230V – 300V / OFF Over-Voltage Recovery 225V – 295V Under-Voltage Trip 140V – 210V / OFF Under-Voltage Recovery 145V – 215V Over-Current Limit 1A – 63A Power-On Delay 1s – 500s Installation & Troubleshooting : Fits standard 35mm DIN rails. Use only the provided charger or a compatible USB-C charger
: Connect the power supply to the "IN" terminals (typically at the top) and the load to the "OUT" terminals. LED Indicators V Flashing
: Indicates an active over or under-voltage protection event. A Flashing : Indicates an active over-current event. setting codes for this specific model?
1. The display is blank.
Check your wiring on the L and N input terminals. If the battery is completely dead (from long storage), it may need to be powered on for a few minutes to charge the internal battery before the screen activates.
Safety Notes
- Use only the provided charger or a compatible USB-C charger.
- Keep away from water and extreme temperatures.
- Not intended for use by minors or pregnant individuals.
- Do not modify the device.
What’s in the Box
- TOVPD160EC device
- Magnetic mouthpiece
- Ceramic heating chamber / pod
- Concentrate pad
- Packing tool / dab tool
- USB-C charging cable
- User quick-start guide